Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 115
Filter
1.
Article in English | MEDLINE | ID: mdl-38423848

ABSTRACT

PURPOSE: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS). METHODS: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up. RESULTS: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %). CONCLUSIONS: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.

2.
Open Heart ; 11(1)2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38191233

ABSTRACT

BACKGROUND: A quarter of patients with severe aortic stenosis (AS) were asymptomatic, and only a third of them survived at the end of 4 years. Only a select subset of these patients was recommended for aortic valve replacement (AVR) by the current American College of Cardiology/American Heart Association guidelines. We intended to study the effect of early AVR (eAVR) in this subset of asymptomatic patients with preserved left ventricle function. METHODS AND RESULTS: We searched PubMed and Embase for randomised and observational studies comparing the effect of eAVR versus conservative therapy in patients with severe, asymptomatic AS and normal left ventricular function. The primary outcome was all-cause mortality. The secondary outcomes were composite major adverse cardiac events (MACE) (study defined), myocardial infarction (MI), stroke, cardiac death, sudden death, the development of symptoms, heart failure hospitalisations and major bleeding. We used GRADEPro to assess the certainty of the evidence. In the randomised controlled trial (RCT) only analysis, we found no significant difference in all-cause mortality between the early aortic intervention group versus the conservative arm (CA) (incidence rate ratio, IRR (CI): 0.5 (0.2 to 1.1), I2=31%, p=0.09). However, in the overall cohort, we found mortality benefit for eAVR over CA (IRR (CI): 0.4 (0.3 to 0.7), I2=84%, p<0.01). There were significantly lower MACE, cardiac death, sudden death, development of symptoms and heart failure hospitalisations in the eAVR group. We noticed no difference in MI, stroke and major bleeding. CONCLUSION: We conclude that there is no reduction in all-cause mortality in the eAVR arm in patients with asymptomatic AS with preserved ejection fraction. However, eAVR reduces heart failure related hospitalisations and death or heart failure hospitalisations. PROSPERO REGISTRATION NUMBER: CRD42022306132.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Conservative Treatment/adverse effects , Death, Sudden, Cardiac/etiology , Heart Failure/etiology , Hemorrhage/etiology , Myocardial Infarction/etiology , Stroke/etiology , United States , Ventricular Function, Left , Heart Valve Prosthesis Implantation/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects
3.
Rev. esp. cardiol. (Ed. impr.) ; 76(11): 872-880, Nov. 2023. tab, graf, ilus
Article in Spanish | IBECS | ID: ibc-226971

ABSTRACT

Introducción y objetivos: La última generación de válvulas cardiacas expandibles con balón y autoexpandibles para implante percutáneo no se han comparado en valvulopatía aórtica bicúspide (VAB).Métodos: Registro multicéntrico de pacientes consecutivos con VAB y estenosis grave tratados con las válvulas cardiacas expandibles con balón (Myval y SAPIEN 3 Ultra [S3U]) o autoexpandible Evolut PRO+(EP+). Se realizó un análisis de tripletes mediante el software TriMatch para minimizar el impacto de las diferencias basales. El objetivo primario del estudio fue evaluar la tasa de éxito del dispositivo a 30 días y los objetivos secundarios, el objetivo combinado de seguridad y sus componentes individuales a 30 días.Resultados: Se incluyó a 360 pacientes (media de edad, 76,6±7,6 años; el 71,9% varones); 122 con Myval (33,9%), 129 con S3U (35,8%) y 109 con EP+(30,3%). La media de puntuación STS fue de 3,6±1,9%. No hubo ningún caso de oclusión coronaria, rotura de anillo, disección aórtica o mortalidad periprocedimiento. El evento primario de éxito del dispositivo a 30-días fue significativamente superior en el grupo que recibió Myval (Myval, 100%; S3U, 87,5%, y EP+, 81,3%), fundamentalmente a expensas de mayor gradiente residual con S3U y mayor tasa de insuficiencia aórtica al menos moderada con EP+. La tasa no ajustada de implante de marcapasos no presentó diferencias significativas.Conclusiones: En la VAB con estenosis grave y cirugía contraindicada, Myval, S3U y EP+tuvieron una seguridad comparable, aunque Myval presentó mejor gradiente residual que S3U y ambos dispositivos expandibles con balón resultaron en menos fuga perivalvular residual que EP+. Por lo tanto, ajustándose a los riesgos específicos de cada paciente, se puede seleccionar cualquiera de los 3 dispositivos con resultados óptimos.(AU)


Introduction and objectives: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis.Methods: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days.Results: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation.Conclusions: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.(AU)


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Heart Valve Prosthesis/adverse effects , Aortic Valve Stenosis , Heart Valves , Cardiology , Cardiovascular Diseases , Heart Valve Prosthesis/statistics & numerical data , Heart Valve Prosthesis/trends
4.
6.
Interv Cardiol ; 18: e12, 2023.
Article in English | MEDLINE | ID: mdl-37398875

ABSTRACT

Transcatheter aortic valve implantation (TAVI) performed using femoral arterial access is now a guideline recommended treatment for severe calcific aortic stenosis (AS) in elderly patients. Technological advancements and procedural refinements have focused on making TAVI simpler, safer, more effective and durable. Myval (Meril Lifesciences) is a new generation balloon-expandable transcatheter heart valve (THV) developed in India that possesses novel features to improve deliverability and aid precise deployment. Following the first-in-human study, Myval was approved in India for commercial implantation in October 2018 and was subsequently given a CE mark in April 2019. This article reviews the science, technology and up-to-date clinical evidence for the Myval THV.

7.
Int J Cardiol ; 382: 68-75, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37028710

ABSTRACT

BACKGROUND: The balloon expandable Myval transcatheter heart valve (THV) showed encouraging results regarding residual aortic regurgitation (AR) from multiple observational studies. The newly designed Myval Octacor has been introduced recently, aiming for a reduction in AR and improved performance. OBJECTIVES: The focus of this study is to report the incidence of AR using the validated quantitative Videodensitometry angiography technology (qLVOT-AR%) in the first in human use of the Myval Octacor THV system. METHODOLOGY: We report on the first in human use of the Myval Octacor THV system in 125 patients in 18 Indian centres. Independent retrospective analysis of the final aortograms following implantation of the Myval Octacor was performed using the CAAS-A-Valve software. AR is reported as a regurgitation fraction. The previously validated cutoff values have been used to identify ≥moderate AR (RF% >17%), mild (6% < RF% ≤17%), and none or trace AR (RF% ≤ 6%). RESULTS: Final aortogram was analysable for 103 patients (84.4%) among the 122 available aortograms. 64 (62%) patients, had tricuspid aortic valve (TAV), 38 (37%) with bicuspid AV (BAV), and one with unicuspid AV. The median absolute RF% was 2% [1, 6], moderate or more AR incidence was 1.9%, mild AR in 20.4%, and none or trace AR in 77.7%. The two cases with RF% >17% were in the BAV group. CONCLUSION: The initial results of Myval Octacor using quantitative angiography-derived regurgitation fraction demonstrated a favourable outcome regarding residual AR, possibly due to improved device design. Results must be confirmed in a larger randomised study, including other imaging modalities.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/epidemiology , Aortic Valve Stenosis/surgery , Aortography/methods , Heart Valve Prosthesis/adverse effects , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
AsiaIntervention ; 9(1): 18-19, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36936102
10.
J Clin Med ; 12(6)2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36983397

ABSTRACT

BACKGROUND: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. AIM: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. METHODS AND RESULTS: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. CONCLUSIONS: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.

11.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Article in English, Spanish | MEDLINE | ID: mdl-36898524

ABSTRACT

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged , Aged, 80 and over , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Constriction, Pathologic , Treatment Outcome , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Heart Valve Diseases/complications , Heart Valve Diseases/surgery , Bicuspid Aortic Valve Disease/surgery , Prosthesis Design
12.
Int J Cardiol ; 376: 35-45, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36657566

ABSTRACT

BACKGROUND: Transcatheter aortic and mitral valve-in-valve (ViV) or valve-in-ring (ViR) implantation into failed bioprosthetic heart valves (BHVs) or rings represents an appealing, less invasive, treatment option for patients at high surgical risk. Nowadays, few data have been reported on the use of balloon-expandable Myval (Meril Life Science, Vapi, India) transcatheter heart valve (THV) for the treatment of degenerated BHVs or rings. We aimed at evaluating the early and mid-term clinical outcomes of patients with left side heart bioprosthesis deterioration treated with transcatheter ViV/ViR implantation using Myval THV. METHODS: 97 consecutive patients with symptomatic, severe aortic(n=33) and mitral(n=64) BHVs/ring dysfunction underwent transcatheter aortic ViV and mitral ViV/ViR implantation with Myval THV. RESULTS: Technical success was achieved in 95 (98%) of the patients. Two cases of acute structural trans-catheter mitral ViV/ViR dysfunction requiring a second THV implantation were reported. At 30-day, a significant reduction in prosthetic trans-valvular pressure gradients and increase in valve areas were seen following both aortic and mitral ViV/ViR implantation. Overall survival at 15 months (IQR 8-21) was 92%. Patients undergoing mitral ViV/ViR had a relatively worse survival compared with those undergoing aortic ViV implantation (89% vs. 97% respectively; HR:2.7,CI:0.33-22.7;p=0.34). At longest follow-up available a significant improvement in NYHA functional class I and II was observed in patients with aortic and mitral ViV/ViR implantation(93.8% and 92.1%). CONCLUSIONS: Despite high surgical risk, transcatheter ViV/ViR implantation for failed left side heart bioprosthesis can be performed safely using Myval THV with a high success rate and low early and mid-term mortality and morbidity.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Follow-Up Studies , Prosthesis Failure , Treatment Outcome , Mitral Valve/surgery , Aortic Valve/surgery , Catheters , Bioprosthesis/adverse effects , Prosthesis Design
14.
Nat Rev Cardiol ; 20(1): 52-67, 2023 01.
Article in English | MEDLINE | ID: mdl-35726019

ABSTRACT

Indications for transcatheter aortic valve implantation (TAVI) have expanded in many countries to include patients with aortic stenosis who are at low surgical risk, and a similar expansion to this cohort is anticipated elsewhere in the world, together with an increase in the proportion of patients with bicuspid aortic valve (BAV) morphology as the age of the patients being treated decreases. To date, patients with BAV have been excluded from major randomized trials of TAVI owing to anatomical considerations. As a consequence, BAV has been a relative contraindication to the use of TAVI in international guidelines. Although clinical experience and observational data are accumulating, BAV presents numerous anatomical challenges for successful TAVI, despite advances in device design. Furthermore, in those with BAV, substantial geographical variation exists in patient characteristics, clinical approach and procedural strategy. Therefore, in this Roadmap article, we summarize the existing evidence and provide consensus recommendations from an international group of experts on the application of TAVI in patients with BAV in advance of the anticipated growth in the use of this procedure in this challenging cohort of patients.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Diseases/surgery , Heart Valve Diseases/etiology , Mitral Valve , Treatment Outcome , Bicuspid Aortic Valve Disease/etiology , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/surgery , Reference Standards
15.
JACC Asia ; 2(5): 559-571, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36518723

ABSTRACT

Background: Implantable cardioverter-defibrillator (ICD) implantation to prevent sudden cardiac death (SCD) in post-myocardial infarction (MI) patients varies by geography but remains low in many regions despite guideline recommendations. Objectives: This study aimed to characterize the care pathway of post-MI patients and understand barriers to referral for further SCD risk stratification and management in patients meeting referral criteria. Methods: This prospective, nonrandomized, multi-nation study included patients ≥18 years of age, with an acute MI ≤30 days and left ventricular ejection fraction <50% ≤14 days post-MI. The primary endpoint was defined as the physician's decision to refer a patient for SCD stratification and management. Results: In total, 1,491 post-MI patients were enrolled (60.2 ± 12.0 years of age, 82.4% male). During the study, 26.7% (n = 398) of patients met criteria for further SCD risk stratification; however, only 59.3% of those meeting criteria (n = 236; 95% CI: 54.4%-64.0%) were referred for a visit. Of patients referred for SCD risk stratification and management, 94.9% (n = 224) attended the visit of which 56.7% (n =127; 95% CI: 50.1%-63.0%) met ICD indication criteria. Of patients who met ICD indication criteria, 14.2% (n = 18) were implanted. Conclusions: We found that ∼40% of patients meeting criteria were not referred for further SCD risk stratification and management and ∼85% of patients who met ICD indications did not receive a guideline-directed ICD. Physician and patient reasons for refusing referral to SCD risk stratification and management or ICD implant varied by geography suggesting that improvement will require both physician- and patient-focused approaches. (Improve Sudden Cardiac Arrest [SCA] Bridge Study; NCT03715790).

16.
AsiaIntervention ; 8(2): 75-85, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36483283

ABSTRACT

Over the past decade, percutaneous left ventricular assist devices (pLVAD), such as the Impella microaxial flow pump (Abiomed), have been increasingly used to provide haemodynamic support during complex and high-risk revascularisation procedures to reduce the risk of intraprocedural haemodynamic compromise and to facilitate complete and optimal revascularisation. A global consensus on patient selection for the use of pLVADs, however, is currently lacking. Access to these devices is different across the world, thus, individual health care environments need to create and refine patient selection paradigms to optimise the use of these devices. The Impella pLVAD has recently been introduced in India and is being used in several centres in the management of high-risk percutaneous coronary intervention (PCI) and cardiogenic shock. With this increasing utilisation, there is a need for a standardised evaluation protocol to guide Impella use that factors in the unique economic and infrastructural characteristics of India's health care system to ensure that the needs of patients are optimally managed. In this consensus document, we present an algorithm to guide Impella use in Indian patients: to establish a standardised patient selection and usage paradigm that will allow both optimal patient outcomes and ongoing data collection.

18.
J Clin Med ; 11(17)2022 Sep 02.
Article in English | MEDLINE | ID: mdl-36079140

ABSTRACT

Background: The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Methods: Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device. Results: A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm2 (range: 171 to 221 mm2). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events. Conclusions: Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration.

19.
Front Cardiovasc Med ; 9: 817705, 2022.
Article in English | MEDLINE | ID: mdl-35966565

ABSTRACT

Background: Transcatheter aortic valve implantation (TAVI) is challenging in bicuspid aortic valve (BAV) anatomy. The patients are young, morphological phenotypes are many, calcium burden is high and there are technical challenges for best outcomes. Observational studies and registries are available with favorable data and experiences from around the world sharing methodologies and algorithms for sizing and implantation. We, therefore, analysed our data of procedural and in-hospital outcomes of TAVI in Bicuspid Aortic Valve cases performed at two high volume centres in India and their follow up for two years. Methods and Results: The data were collated and analysed from two centres (Fortis Escorts Heart Institute, New Delhi and Apollo Hospitals, Chennai) in India for patients who underwent TAVI in a BAV anatomy. It included a total of 70 cases from 2 centres. All symptomatic severe AS patients more than and equal to 65 years having bicuspid anatomy were included in the study irrespective of their STS score. Patients under 65 years of age were advised TAVI only if they were at high risk for open heart surgery. These patients were followed for a period of 2 years and the data were analysed. Pre TAVI imaging tools utilised were 2D echo, transthoracic echocardiography (TTE), trans oesophageal echocardiography (TEE), and ECG gated multi slice CT (MSCT) scan imaging. MSCT was utilised for confirmation of the anatomy and classifying the morphological type of valve, measuring, and evaluating all anatomic determinants of aortic root complex for planning the procedure and choice of the valve and its size. Sizing in balloon expanding valve (BEV) and self-expanding valve sizing (SEV) were based primarily on annulus area and perimeter, respectively. The SEV used in our study were the Core Valve and Evolut R (Medtronic, United States) and the BEVs included Sapien3 (Edwards Lifesciences, United States) and Myval (Meril Lifesciences, India). The BAV cohort constituted 24.4% of the total 287 TAVI cases, followed up for 2 years. The mean age of these patients was 72 years. The incidence of male patients was 68.57% and female patients was 31.4%. The Sievers type 1 included 78.5%, type 0 were 21.4% of the cases and there was no case of type 2 in the study. The procedural success was to the tune of 98%. Patients with normal left ventricular ejection fraction (LVEF) improved their symptoms class after TAVI and remained so at 2 years follow up. The poor LVEF subset of patients did not have heart failure admissions and also had improvement in their symptom status. The peak-to-peak aortic valve gradient decreased to 0 mmHg at the end of the procedure in most of the cases. The mean pressure gradient (PG) across the new valve ranged between 0 and 15 mmHg and the aortic valve area (AVA) was close to 2 cm2. These numbers were consistent at 2 years follow up. Significant paravalvular leak (PVL) 24.28% was seen immediately after deployment of the valve in heavily calcified anatomy but it reduced to mild or trivial PVL after post-dilation and one patient needed a second valve to treat PVL. No patient had more than mild PVL with either type of valve at the end of the procedure. Permanent pacemaker implantation (PPI) was required in 11.4% of the patients within 24 h to 7 days of the procedure. No one needed a PPI in the 2 year follow up. Coronary occlusion did not happen to any patient. No patient had a disabling stroke. Non-disabling stroke was seen in 10% of cases and mostly in the first week or 30 days of the procedure and the incidence was more with BEV (14%) as compared to SEV (8%). There was one case of valve embolisation after 24 h of the procedure, which needed a surgical valve replacement. There was no case of annular injury or injury to other parts of the aortic root complex. Two cases had access vessel (femoral artery) thrombosis at end of the procedure and a third patient had proglide related residual stenosis. Two cases had acute kidney injury and needed dialysis. There was no major bleeding complication in any patient. Peri procedural mortality occurred in two patients. Valve thrombosis was seen in one patient after 3 months, which was treated with oral anticoagulation. Valve degeneration and failure or infective endocarditis were not seen in any patient. Conclusion: The patients with BAV stenosis who underwent TAVI in this study had good procedural success rates and clinical outcomes. The haemodynamics achieved with both SEV and BEV were good at 2 years. The rates of PVL, PPI, and stroke are similar to that of many other studies and registries. PPI rate and non-disabling stroke incidence appear to be higher similar to many studies done. There was no case of coronary occlusion in the study. Meticulous CT analysis of the aortic root complex, selection of appropriate type and size of the valve, and best implantation practices along with cerebral protection will probably be the key to safer and more successful TAVI in this population.

SELECTION OF CITATIONS
SEARCH DETAIL
...